Jens Hauser
2018-11-18 14:46:41 UTC
Hello List,
I had a Windows Server 2016 as a DomU on a Debian 8.11 now up and running
for about 6 month without any problems. The system contains an Exchange
Server - everything worked smooth.
On last Friday the system seems to have rebooted due to Windows updates
automatically installed. After that I found the server freezed in a screen
with the no longer animated icons.
Another 2012 R2 server was running fine without any problems.
So I tried to find out whats wrong and narrowed it down tot he network
driver as far as I can tell. I found entries in ntbtlog.txt which said that
"AFD.SYS" was not loaded at boot.
The first tries I was unable to boot into safe mode. After a few hickups the
system booted into Safe Mode saying that an upgrade didn't work and that it
was to be rolled back. After that I was able to get into Safe Mode but first
only the one without network drivers.
If I disable Realtek RTL8139 C network card I can boot into normal
operation. With this network card enabled the boot hangs as before.
After installation of Xen Project Win PV drivers 8.2.1 all the necessary
devices where found but a reboot leads tot he Windows screen with the
animated icons floating endlessly.
It all seems to be related to network stuff. There is this Realtek Card
which needs to be disabled and it's not vanishing if I install the PV
drivers - even if the Xen PV Network Device #0 is showing up the Realtek
Card is still there.
Is there any chance to fix this issue? Or do I need to install the server as
a new system?
Kind regards,
Jens
I had a Windows Server 2016 as a DomU on a Debian 8.11 now up and running
for about 6 month without any problems. The system contains an Exchange
Server - everything worked smooth.
On last Friday the system seems to have rebooted due to Windows updates
automatically installed. After that I found the server freezed in a screen
with the no longer animated icons.
Another 2012 R2 server was running fine without any problems.
So I tried to find out whats wrong and narrowed it down tot he network
driver as far as I can tell. I found entries in ntbtlog.txt which said that
"AFD.SYS" was not loaded at boot.
The first tries I was unable to boot into safe mode. After a few hickups the
system booted into Safe Mode saying that an upgrade didn't work and that it
was to be rolled back. After that I was able to get into Safe Mode but first
only the one without network drivers.
If I disable Realtek RTL8139 C network card I can boot into normal
operation. With this network card enabled the boot hangs as before.
After installation of Xen Project Win PV drivers 8.2.1 all the necessary
devices where found but a reboot leads tot he Windows screen with the
animated icons floating endlessly.
It all seems to be related to network stuff. There is this Realtek Card
which needs to be disabled and it's not vanishing if I install the PV
drivers - even if the Xen PV Network Device #0 is showing up the Realtek
Card is still there.
Is there any chance to fix this issue? Or do I need to install the server as
a new system?
Kind regards,
Jens